relion premier classic user manual
ReliOn PREMIER CLASSIC Blood Glucose Meter User Manual
This user manual provides instructions on how to use the ReliOn PREMIER CLASSIC Blood Glucose Meter. It covers topics such as getting started, using the meter, test strip insertion, blood sample collection, reading results, cleaning and disinfection, battery replacement, storage and disposal, warranty information, safety information, and contact information.
Introduction
Welcome to the ReliOn PREMIER CLASSIC Blood Glucose Monitoring System. This system is designed to help people with diabetes manage their condition by providing accurate and reliable glucose readings. The ReliOn PREMIER CLASSIC Blood Glucose Meter is a user-friendly device that requires a small blood sample for testing. It features a large, easy-to-read display, a convenient size for portability, and a 5-second test time. This manual provides comprehensive instructions on how to use the meter effectively and safely. We encourage you to read it carefully before using the ReliOn PREMIER CLASSIC Blood Glucose Meter. This will ensure that you understand all aspects of the system and can use it correctly to monitor your blood glucose levels.
Features
The ReliOn PREMIER CLASSIC Blood Glucose Meter boasts a range of features designed to make blood glucose monitoring simple and efficient. It requires no coding, simplifying setup and eliminating potential errors. The meter delivers accurate results within 5 seconds, allowing for quick and timely blood sugar readings. The ReliOn PREMIER CLASSIC also features a large, easy-to-read display, making it simple to view test results. For added convenience, the meter tracks total blood glucose readings, as well as pre-meal and post-meal averages, providing a comprehensive overview of your blood sugar patterns. The ReliOn PREMIER CLASSIC Blood Glucose Meter is a valuable tool for individuals with diabetes, enabling them to effectively manage their condition and make informed decisions about their health.
Getting Started
Before using the ReliOn PREMIER CLASSIC Blood Glucose Meter, it’s crucial to familiarize yourself with the included materials and instructions. The kit includes the meter itself, a lancing device with 10 lancets, 50 test strips, a user manual, a quick reference guide, and a logbook. Start by carefully reading through the user manual, paying special attention to the safety information and instructions for using the meter. Next, insert the batteries into the meter and set the time and date. The ReliOn PREMIER CLASSIC requires no coding, so you can proceed directly to inserting a test strip into the meter. Ensure the test strip is facing the correct way with the contact bars facing upwards. The meter will automatically turn on and display a symbol once the test strip is inserted. You are now ready to collect a blood sample and begin testing your blood glucose levels.
Using the Meter
The ReliOn PREMIER CLASSIC Blood Glucose Meter is designed for ease of use and accurate results; To begin testing, select a lancet from the lancing device and insert it into the lancet holder. Choose a lancet depth that is comfortable for you, and use the lancing device to prick your finger. A small drop of blood will form. Gently apply the drop of blood to the test strip’s blood application area, ensuring the blood completely fills the area. The meter will automatically draw the blood into the test strip and start the countdown. Within seconds, your blood glucose reading will be displayed on the meter’s screen. The meter provides a clear and concise reading in mg/dL (milligrams per deciliter), making it easy to understand your blood glucose levels. After testing, dispose of the used test strip properly and store the meter in a safe and dry place.
Test Strip Insertion
Inserting the test strip into the ReliOn PREMIER CLASSIC Blood Glucose Meter is a simple process. Ensure the meter is off, and locate the test strip port on the side of the meter. Take a new test strip and check for the contact bars on one end. Align the test strip with the contact bars facing upwards and gently insert it into the test strip port. Push the test strip in until it clicks into place, and the meter will automatically turn on. The meter will display the symbol, indicating the test strip is correctly inserted and ready for use. Always ensure the test strip is properly inserted before applying blood, as improper insertion can result in inaccurate readings. Never use a test strip that is past its expiration date, as it may not provide accurate results.
Blood Sample Collection
Collecting a blood sample for your ReliOn PREMIER CLASSIC Blood Glucose Meter is a straightforward process. First, wash your hands thoroughly with soap and water and dry them completely. Choose a lancing device appropriate for your needs and insert a new lancet. Select a fingertip, avoiding areas with calluses or cuts. Using the lancing device, gently puncture the chosen fingertip. Massage the fingertip gently to encourage blood flow. Hold the fingertip over the test strip port, and a small drop of blood will appear. Do not squeeze the fingertip, as this can contaminate the sample. Allow the blood to fill the test strip completely, and the meter will automatically begin the analysis. Once the blood sample is collected, dispose of the lancet safely and wash your hands again.
Reading Results
The ReliOn PREMIER CLASSIC Blood Glucose Meter will display your blood glucose reading in milligrams per deciliter (mg/dL) after a brief processing time. The reading will be accompanied by a symbol indicating the status of the test, such as a “high” or “low” alert. The meter also stores your blood glucose readings in its memory, allowing you to track your blood sugar levels over time. To access this information, you can review the logbook that comes with the meter or use the meter’s built-in memory function. The readings can be used to help you manage your diabetes effectively and to make informed decisions about your diet, exercise, and medication. It’s essential to consult with your healthcare professional to interpret your blood glucose readings and discuss any concerns you may have.
Calibration and Control Solutions
Calibration and control solutions are essential for ensuring the accuracy of your ReliOn PREMIER CLASSIC Blood Glucose Meter. These solutions are designed to mimic the blood glucose levels of a healthy individual and are used to check if the meter is functioning properly. It’s crucial to use these solutions regularly as instructed by your healthcare provider. They help in identifying any potential issues with the meter, allowing you to get it serviced or replaced if necessary. Regular calibration and control solution testing are vital in maintaining the reliability of your blood glucose readings, ensuring you receive accurate information to manage your diabetes effectively.
Cleaning and Disinfection
Keeping your ReliOn PREMIER CLASSIC Blood Glucose Meter clean and disinfected is crucial to ensure accurate and reliable blood glucose readings. After each use, gently wipe the meter’s surface with a soft, clean cloth dampened with a mild detergent solution. Avoid using harsh chemicals, abrasives, or alcohol, as these can damage the meter. The test strip port requires special attention. Ensure it is free from any debris or blood residue. Use a clean, dry cotton swab to gently remove any remaining particles. For a thorough disinfection, refer to the cleaning and disinfection instructions outlined in your ReliOn PREMIER CLASSIC Blood Glucose Meter user manual. Regular cleaning and disinfection practices help maintain the meter’s accuracy and longevity, ensuring its reliability for your diabetes management.
Troubleshooting
While the ReliOn PREMIER CLASSIC Blood Glucose Meter is designed for ease of use and accuracy, you may encounter occasional issues. If your meter displays an error message, refer to the troubleshooting section in your user manual for specific guidance. Common issues include test strip errors, low battery warnings, or communication problems with the device. In case of a test strip error, ensure the test strip is properly inserted and hasn’t expired. If the battery is low, replace it with fresh batteries. If you experience communication problems with the meter, check the connection between the meter and any external devices, such as a smartphone or tablet; If the issue persists, contact ReliOn customer support for assistance. They can provide expert advice and support to resolve any technical difficulties you may encounter.
Battery Replacement
The ReliOn PREMIER CLASSIC Blood Glucose Meter requires two CR2032 lithium batteries for operation; When the battery icon on the meter display blinks, it indicates that the batteries need to be replaced. To replace the batteries, follow these stepsā 1. Turn the meter off. 2. Locate the battery compartment at the back of the meter. 3. Use a small coin or a tool to gently pry open the battery compartment cover. 4. Remove the old batteries by carefully lifting them out of the compartment. 5. Insert two new CR2032 lithium batteries, ensuring that the positive (+) side of the batteries faces up. 6. Close the battery compartment cover securely. 7. Turn the meter on and check if it is functioning properly. Always dispose of used batteries properly and in accordance with local regulations. Ensure you use high-quality batteries from a reputable brand to ensure optimal performance and longevity of your meter.
Storage and Disposal
Proper storage and disposal of your ReliOn PREMIER CLASSIC Blood Glucose Meter and its components are essential to maintain its performance and ensure safety. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it out of reach of children and pets. Do not store the meter in a humid environment, as this can damage the electronic components. When disposing of the meter, lancets, and test strips, follow your local waste disposal regulations. The meter should be disposed of separately from household waste, preferably at a designated electronic waste collection point. Used lancets should be disposed of in a sharps container, while test strips can be disposed of in regular household waste. Remember to always consult your local waste disposal guidelines for proper handling of medical waste.
Warranty Information
The ReliOn PREMIER CLASSIC Blood Glucose Meter is covered by a limited warranty. This warranty covers defects in materials and workmanship for a specific period, typically one year from the date of purchase. To obtain warranty service, you must contact the manufacturer or authorized retailer with proof of purchase. The warranty does not cover damage caused by misuse, neglect, accident, or unauthorized repairs. It also does not cover consumable items like test strips or lancets. For complete details regarding warranty terms and conditions, refer to the warranty information provided with the meter or available on the manufacturer’s website. This information will outline the specific coverage, exclusions, and procedures for obtaining warranty service.
Safety Information
The ReliOn PREMIER CLASSIC Blood Glucose Meter is designed for safe and effective use. However, it’s important to follow all safety precautions to minimize the risk of injury or damage. Always read and understand the instructions before using the meter and follow the recommendations provided in this manual. Never share the meter with others, as this can lead to inaccurate readings and potential health risks. Keep the meter and its accessories out of reach of children and pets. Avoid using the meter in extreme temperatures or humid environments. If you experience any malfunctions or have any concerns about the meter’s operation, discontinue use and contact the manufacturer or your healthcare provider immediately.
Contact Information
If you have any questions or concerns about the ReliOn PREMIER CLASSIC Blood Glucose Meter, you can contact the manufacturer or your healthcare provider. The manufacturer’s contact information can be found on the product packaging or on their website. You can also find a list of certified diabetes educators and other resources on the American Diabetes Association (ADA) website. The ADA is a leading organization dedicated to providing support and education for people with diabetes and their families. If you are experiencing any health concerns related to your diabetes, it is important to seek medical advice from a qualified healthcare professional.
Appendix
The appendix of the ReliOn PREMIER CLASSIC Blood Glucose Meter user manual provides additional information and resources that may be helpful to users. This section often includes a glossary of terms, troubleshooting tips, a list of frequently asked questions (FAQs), and contact information for customer support. It may also contain detailed instructions on how to perform specific tasks, such as calibrating the meter or changing the batteries. The appendix serves as a valuable reference guide for users who need further clarification or assistance with the meter.